Accessories for CS328A device
Supplied accessories for Cleverscope CS328A
- 2x oscilloscope probes 250MHz (switchable attenuation x1, x10) - type CS1001
- CS1004/CS1005 8 bit 100MHz digital input pods including probes
- Power Supply Unit and lead
- CD-ROM with software and documentation
- Interconnecting USB cable
- Printed user guide
Optional accessories for
Cleverscope CS328A
CS1001: Oscilloscope probe 250MHz (attenuation x1or x10)
Accessory type: Oscilloscope probe / sensor
The CS1001 Analog probe is a passive high impedance oscilloscope probe designed and calibrated for use with instruments having an input impedance of 1 MOhm shunted by 20pF. However, it may be compensated for use with instruments having an input capacitance of 10 to 35pF. The probe incorporates a three position slide switch in the head which selects attenuation of x1, x10 or ground reference position
Technical specifications:
- Attenuation ratio: 1:1 , 1:10
- Frequency range: DC to 250MHz
- Input resistance: 1M Ohm (x1) / 10M Ohm (x10)
- Input capacitance: 17pF
- Compensation range: 10pF-30pF
- Cable length: 1,2m
CS1002: Oscilloscope probe 250MHz (attenuation x100)
Accessory type: Oscilloscope probe / sensor
CS1002 is a low-input capacitance high voltage oscilloscope probe designed and calibrated for use with instruments having an input impedance of 1 MOhm shunted by 5.5pF. However, it may be compensated for use with instruments having an input capacitance of 10 to 35pF.
Technical specification:
- Attenuation ratio: 100:1
- Frequency range: DC to 250MHz
- Input impedance: 100MOhm || 5.5 pF
- Compensation range: 10pF až 35pF
- Working voltage: 1500Vrms, CAT II
- Cable length: 1,3m
CS1003: Oscilloscope probe 50MHz (attenuation x1000)
Accessory type: Oscilloscope probe / sensor
CS1003 is high-voltage oscilloscope probe designed and calibrated for use with instruments having an input impedance of 1 MOhm shunted by 3pF. However, it may be compensated for use with instruments having an input capacitance of 10 to 35pF.
Technical specification:
- Attenuation Ratio: 1000:1
- Frequency range: 50MHz
- Input impedance: 100MOhm || 3pF
- Compensation range: 5pF až 50pF
- Working Voltage: DC:1.5kV; AC Pulse: 30kV p-p; Sine Wave:10kVrms
- Cable length: 2m
CS1030: Differential oscilloscope probe 25MHz (attenuation x20, x50, x200)
Accessory type: Oscilloscope probe / sensor
CS1030 is an active differential oscilloscope probe with switchable ranges (x20, x50,x 200) designed for making isolated measurements between any two points in a system.
Accessories that are included with the differential probe are:Carry Bag, Instruction Manual, Large Crocodile Clips, Long Grabber Clips, Test leads, BNC-BNC cable, Power supply.
Technical specification:
- Attenuation ranges: 20:1, 50:1, 200:1 (1M Ohm), 40:1 100:1 400:1 (50 Ohm)
- Frequency range: 15MHz (range x20), 25 MHz ( range x50, x200)
- Input impedance: 4 MΩ 1.2 pF (between inputs), 2 MΩ 2.3 pF (between input and ground)
- Max Differential Voltage: 1300V (DC +peak AC)
- Max Voltage to Ground: 1000V (DC +peak AC)
- Safety standard: IEC1010-1 Cat 1. EN61010, UL3111
- Cable length: 2m
- Power supply: One internal 9V PP3 battery or external 6-9V DC
CS1031: Differential oscilloscope probe 50MHz (x100, x200, x500, x1000)
Accessory type: Oscilloscope probe / sensor
The CS1031 is an active differential probe with switchable ranges of attenuation (x100, x200, x500 and x1000) with 50 MHz bandwidth designed for making isolated measurements between any two points in a system.
Accessories that are included with the differential probe are:Carry Bag, Instruction Manual, Large Crocodile Clips, Long Grabber Clips, Test leads, BNC-BNC cable, Power supply.
Technical specification:
- Attenuation ranges: 100:1, 200:1, 500:1, 1000:1 (1M Ohm), 200:1, 400:1, 1000:1, 2000:1 (50 Ohm)
- Frequency range: 25MHz ( range x100), 50 MHz (range x200, x500, x1000)
- Input impedance: 4 MΩ 1.2 pF (between inputs), 2 MΩ 2.3 pF (between input and ground)
- Max Differential Voltage: ±6500V (DC + peak AC)
- Max Voltage to Ground: 6500V (DC + peak AC)
- Safety standard: IEC1010 Cat 1. EN61010, UL3111
- Cable length: 1m
- Power supply: One internal 9V PP3 battery or external 6-9V DC
CS1004: Digital probe pods cable for CS328A device (channels 1-4)
Accessory type: Cable - wiring
Spare cable of digital probe pods for logic analyzer inputs (CH1-CH4) of Cleverscope CS328A device.
Technical specification:
- Number of Signal Inputs: 4
- Bandwidth: 100MHz
- Input Resistance: 100 Ohm
- Working Voltage: -16V až +20V
- Cable Length: 1m
CS1005: Digital probe pods cable for CS328A device (channels 5-8)
Accessory type: Cable - wiring
Spare cable of digital probe pods for logic analyzer inputs (CH5-CH8) of Cleverscope CS328A device.
Technical specification:
- Number of Signal Inputs: 4
- Bandwidth: 100MHz
- Input Resistance: 100 Ohm
- Working Voltage: -16V až +20V
- Cable Length: 1m
CABUSB-AB: Interconnecting USB cable (type A-B)
Accessory type: Cable - wiring
Spare interconnecting USB cable to connect device to the host computer. Cable type: A-B male-male.
CABUSB-AB is designed for use with following devices: ELAB-080, CS328A, CS320A.
Cable length: 1.2m
CS1020: Link cable for Cleverscope devices
Accessory type: Cable - wiring
A short cable to connect two Cleverscope units together via the DIG I/O ports. It allows the trigger from one unit to trigger the channels of the other. It does not matter which way round it is used. This cable is required to link two units together for four channel operation
CS700A: Waveform generator module
Accessory type: Extension module
The CS700A Signal Generator is a plug-in module for the CS328 and CS320 Oscilloscopes. The CS700A Signal generator generates sine, square and triangle output waveforms. The amplitude may be varied between 0 and 5V pk-pk, in 10mV steps. The offset maybe varied from –4 to +4V in 10 mV steps. The generator can be FSK and PSK modulated, and Frequency swept. The sweep may be synchronized with the Spectrum Analyzer to carry out transfer response measurement. Two of the digital inputs may be allocated to switch between either of the two frequencies or two phases. If you order the CS700A at the same time as a CS328A or CS320A, the module will be factory fitted. Otherwise you can easily fit the module yourself.
CS710: Sampler module with 10-bits resolution (2channels, 100MHz)
Accessory type: Extension module
Module CS712U is a sampler plug-in module that provides sampling resolution 10 bits to both analog channels of CS320A or CS328A devices. Sample rate is 100MS/sec. This module is standard supplied sampler module for CS320A and CS328A devices.
CS712: Sampler module with 12-bits resolution (2channels, 100MHz)
Accessory type: Extension module
Module CS712U provides extension of sampling resolution to 12 bits to both analog channels of CS320A or CS328A devices at 100MS/sec sample rate. When this module is ordered at initial order of CS328A or CS320A device, the price is lower (see factory modules - CS712U).
CS714: Sampler module with 14-bits resolution (2channels, 100MHz)
Accessory type: Extension module
Module CS712U provides extension of sampling resolution to 14 bits to both analog channels of CS320A or CS328A devices at 100MS/sec sample rate. When this module is ordered at initial order of CS328A or CS320A device, the price is lower (see factory modules - CS714U).
CS741: Ethernet interface module
Accessory type: Extension module
CS741U module provides possibility to connect the CS320A or CS328A devices via Ethernet interface.
This module replaces the USB interface module.
CS800: Memory module 8M samples for Cleverscope CS320A, CS328A
Accessory type: Exctension module - only factory upgrade
The CS800 provides double the memory (8M samples) of the standard units. As the minimum frames is 2 you can have up to 4Msamples in one capture.
Module CS800 is only available on initial order of the CS328A or CS320A acquisition units.
CS810: External sampler clock interface
Accessory type: Exctension module - only factory upgrade
The CS810 is the factory addition of the facility to use an external sampler clock signal instead of the standard internal 100 MHz source. A 50 Ohm SMA input fitted to the rear panel accepts sine or square wave clocks up to 3V p-p in amplitude with a frequency range of 1-100MHz. The acquisition unit automatically determines the input frequency. The internal/external clock selector switch is software controllable from the application, and contributes less than 0.2pSec of additive jitter. The external clock input enables you to use Cleverscope for synchronous sampling applications.
Module CS810 is only available on initial order of the CS328A or CS320A acquisition units
CS712U: Sampler module with 12-bits resolution (2channels, 100MHz)
Accessory type: Exctension module - only factory upgrade
This plug in module can either be purchased instead of the 10 bit sampler on initial order. Module CS712U provides extension of sampling resolution to 12 bits to both analog channels of CS320A or CS328A devices. The factory upgrade option price is lower than extension module CS712, because the 10-bit sampler is not supplied in this case. If you want to have both samplers then you will need to purchase the extra sampler as a module - although we can not think of a good reason for needing both.
CS712U module is only available on initial order of the CS328A or CS320A acquisition units
CS714U: Sampler module with 14-bits resolution (2channels, 100MHz)
Accessory type: Exctension module - only factory upgrade
This plug in module can either be purchased instead of the 10 bit sampler on initial order. Module CS712U provides extension of sampling resolution to 14 bits to both analog channels of CS320A or CS328A devices. The factory upgrade option price is lower than extension module CS712, because the 10-bit sampler is not supplied in this case. If you want to have both samplers then you will need to purchase the extra sampler as a module - although we can not think of a good reason for needing both.
CS714U module is only available on initial order of the CS328A or CS320A acquisition units
CS741U: Ethernet interface module
Accessory type: Exctension module - only factory upgrade
CS741U module provides possibility to connect the CS320A or CS328A devices via Ethernet interface. This module replaces the USB interface module.
CS741U module is only available on initial order of the CS328A or CS320A acquisition units